Rev. chil. infectol ; 31(6): 670-675, dic. 2014. ilus, tab
Artículo en Español | LILACS | ID: lil-734759

RESUMEN

Introduction: Automated systems have simplified laboratory workflow, improved standardization, traceability and diminished human errors and workload. Although microbiology laboratories have little automation, in recent years new tools for automating pre analytical steps have appeared. Objectives: To assess the performance of an automated streaking machine for urine cultures and its agreement with the conventional manual plating method for semi quantitative colony counts. Materials and Methods: 495 urine samples for urinary culture were inoculated in CPS® agar using our standard protocol and the PREVI™ Isola. Rates of positivity, negativity, polymicrobial growth, bacterial species, colony counts and re-isolation requirements were compared. Results: Agreement was achieved in 98.97% of the positive/negative results, in 99.39% of the polymicrobial growth, 99.76% of bacterial species isolated and in 98.56 % of colony counts. The need for re-isolation of colonies decreased from 12.1% to 1.1% using the automated system. Discussion: PREVI™ Isola's performance was as expected, time saving and improving bacterial isolation. It represents a helpful tool for laboratory automation.


Introducción: Los sistemas automatizados han facilitado el flujo de trabajo, mejorado la estandarización, la trazabilidad, disminuido el error humano y la carga de trabajo en los laboratorios. A pesar de que la microbiología ha permanecido poco automatizada, en los últimos años han aparecido nuevas herramientas para la automatización de la etapa pre analítica. Objetivos: Evaluar el desempeño de un sistema automatizado de siembra de urocultivos y la concordancia con la siembra manual convencional en el recuento semicuantitativo de colonias. Materiales y Métodos: 495 muestras de orinas fueron sembradas según nuestro protocolo habitual y comparadas con las placas de CPS® obtenidas con PREVI™ Isola en cuanto a positividad/negatividad, muestras polimicrobianas, especies de bacterias aisladas, recuentos y necesidad de resembrar. Resultados: Hubo concordancia en 98,97% de los positivos y negativos, en 99,39% de las muestras polimicrobianas, en 99,76% de las especies aisladas y en 98,56% de los recuentos. La necesidad de resiembra disminuyo de 12,1% a un 1,1% usando este sistema automatizado. Discusión: El desempeño de PREVI™ Isola fue el esperado, mejorando el aislamiento bacteriano y el tiempo requerido y representa una buena herramienta para la automatización de laboratorios.


Asunto(s)
Humanos , Automatización de Laboratorios/instrumentación , Urinálisis/instrumentación , Automatización de Laboratorios/métodos , Automatización de Laboratorios/normas , Recuento de Colonia Microbiana , Reproducibilidad de los Resultados , Urinálisis/métodos , Urinálisis/normas
2.
J. bras. patol. med. lab ; 50(1): 26-35, 02/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-704695

RESUMEN

Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA). Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI), intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples) were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples), based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data...


Introdução: O Sysmex® XE-2100D é um analisador hematológico multiparamétrico destinado à realização de testes hematológicos em sangue anticoagulado com ácido etilenodiamino tetra-acético (EDTA). Objetivos: Considerando a sua importância na prática clínica e laboratorial, o objetivo deste estudo foi avaliar seu desempenho analítico, comparando os resultados obtidos com especificações de qualidade descritas na literatura. Material e método: Na avaliação de desempenho analítico, conforme recomendações do documento H26-A2 do Clinical and Laboratory Standards Institute (CLSI), foram incluídos ensaios de verificação da imprecisão intraensaio ou repetitividade, imprecisão entre ensaios ou reprodutibilidade, linearidade, carryover (arraste), avaliação do mecanismo homogeneizador de amostras, sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos (n = 400 amostras) e a comparação entre a contagem diferencial de leucócitos automatizada e a manual (n = 400 amostras), baseada em uma adaptação do documento H20-A2 do CLSI. Resultados: Os ensaios de verificação da repetitividade, reprodutibilidade, linearidade, carryover (arraste) foram satisfatórios conforme especificações do fabricante. O ensaio de sensibilidade clínica do alerta morfológico (flag) de linfócitos atípicos mostrou eficiência, sensibilidade e especificidade de 92,5%; 65,2% e 94,1% respectivamente. Os coeficientes de correlação entre as contagens diferenciais automatizadas e manuais de neutrófilos, linfócitos, monócitos, eosinófilos e basófilos foram de 0,991; 0,99; 0,872; 0,974 e 0,557 respectivamente...


Asunto(s)
Humanos , Automatización de Laboratorios/métodos , Automatización de Laboratorios/normas , Control de Calidad , Pruebas Hematológicas/métodos , Pruebas Hematológicas/normas